FAQ

Move the pipehandler to TRIP or DRILL position. Enter your permission code on the driller’s panel and navigate to COMPONENTS>CALIBRATE>ELEV POS. Press SELECT on the option that corresponds with the pipehandlers current position. Back To all FAQS

Start with the elevators near the floor (bails floated). Slowly raise the blocks until you have reached the first layer change (cable has reached the end of the drum). Take a measurement from the bottom of the elevators down to the floor. This could be a small number. Press SELECT, highlight SETUP press SELECT, highlight …

How do I do a slip and cut height calibration? Read More »

Ensure the battery installed has a charge of 3.6V. Some devices such as a drill line payout are connected to a constant supply of 12 or 24 VDC. Ensure these devices are connected. Also confirm the display panel has an antenna connected. Change the orientation to achieve line of sight to the wireless devices if …

My wireless sensor isn’t transmitting what do I do? Read More »

It is recommended you wait 30 seconds after you remove the old battery before installing a new one. Also ensure two battery clip retainers are installed in the battery compartment to hold the battery secure. Back To all FAQS

The bail angle transmits more frequently than most other devices so the battery doesn’t last as long. Back To all FAQS

It is possible the pressure sensor has been damaged. It is also possible the calibration needs to be adjusted. Call Rigsmart service for assistance. Back To all FAQS

All Rigsmart panels can operate between 12V and 24V DC. You do not need to change any setting in the panel to switch from 12V to 24V. Back To all FAQS

The more information the tech on the phone has about your system helps us serve you better. Back To all FAQS

It is recommended you wait 30 seconds after you remove the old battery before installing a new one. Also ensure two battery clip retainers are installed in the battery compartment to hold the battery secure. Back To all FAQS

When the bails are floated the floor saver limit will typically be set at 0.0 ft (or meters). The Rigsmart system will automatically adjust (lower) this floor saver limit when the bails are tilted out. This allows the blocks to travel to a negative height. Back To all FAQS